Products

Products

Eccentricity and diameter deflection measuring system for the single ferrule of the optical connectors
(YGN‐524SF)

YGN-524SF performs measurement of the eccentricity and internal diameter of a single core ferrule.
Rotate with the V-groove tool and roller and derive the eccentricity of the internal diameter (core) center with respect to a standard external form.
Measures with a high precision using rotating, light intensity control and image processing that are based on a mechanism and software that is designed and produced in-house.Measurement can be performed simply by placing the work and pressing a switch. An arbitrary standard value is entered for each item as an inspection function and an overall rating of OK or NG is displayed.
Two types of measurements for the ferrule capillary and fiber assembly can be taken with a single machine.

System configuration

Configuration Base
Optical system
  • 20X for internal diameter (φ 125 μm)
  • 100X for core (φ 9 μm)
  • LED light source & core light-guiding unit
Rotating mechanism
  • Motor & roller
V-groove tool
  • φ1.25mm&φ2.5mm
Control & image processing unit
  • PC OS Windows 7
  • In-house image processing algorithm
  • Rotating control
  • Intensity control
  • 17-inch LCD monitor
Functions
  • Manual light setting
  • Auto light setting
  • Save image (bmp format)
  • Display/measure saved image
  • Luminance graph display
  • Tolerance input for each measurement item
  • Color change in the value display box (OK: green, NG: red)
  • Results list display
  • Save results (csv format)
  • Display digits 9999.999μm
Performance
  • Eccentricity of measurement precision 3σ ≦ 0.1μm
  • Measurement takt 3.4 [sec] (45° interval/revolution)
Measurement details Ferrule capillary
  • Eccentricity:Eccentricity of center of internal diameter with respect to a standard external form
  • Internal diameter:Derive approximate circle from round image
  • Maximum diameter:Maximum distance of a round image
  • Minimum diameter:Minimum distance of a round image
Fiber assembly parts
  • Eccentricity:Eccentricity of center of internal diameter with respect to a standard external form
  • Core diameter:Derive approximate circle from round image
Auxiliary functions After measuring the key direction feeding function, the core is rotated on the operator side to assist in the adjustment (marking) of the center of the key direction.
Options Work bench
  • MU/LC manual rotating tool (for fitting plug case)
  • SC manual rotating tool (for fitting plug case)
Feel free to contact us for a quotation, request or consultation.
Feel free to contact us for a quotation, request or consultation. You can also send your inquiry via an
online inquiry form.